Stack gas emissions of PCDD/Fs from hospital waste incinerators in China
Gao, Hongcai1,2; Ni, Yuwen1; Zhang, Haijun1; Zhao, Liang1; Zhang, Ning1; Zhang, Xueping1; Zhang, Qing1; Chen, Jiping1; Chen JP(陈吉平)
KeywordPcdd/fs Hospital Waste Incinerators Emission Factors Stack Gas
Source PublicationCHEMOSPHERE
2009-10-01
DOI10.1016/j.chemosphere.2009.08.017
Volume77Issue:5Pages:634-639
Indexed BySCI
SubtypeArticle
Department1
Funding Project103
Contribution Rank1;1
WOS HeadingsScience & Technology ; Life Sciences & Biomedicine
WOS SubjectEnvironmental Sciences
WOS Research AreaEnvironmental Sciences & Ecology
WOS KeywordDIBENZO-P-DIOXINS ; CHLORINE ; PATTERNS ; KOREA ; SOIL ; ASH ; AIR
AbstractStack gas samples from 14 domestic-made hospital waste incinerators (HWIs) in China were collected and analyzed for polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). The waste burning capacities of the investigated HWIs ranged from 5 to 25 ton d(-1). The stack gas emissions of PCDD/Fs from HWIs exhibited a large variation (0.08-31.60 ng I-TEQN m(-3)). Nine incinerators had the emission levels below the current emission standard in China (0.5 ng I-TEQN m(-3)), while only two facilities exhibited emission levels below the European Union directive emission limit (0.1 ng I-TEQ N m(-3)). For two plants, concentrations of PCDD/Fs in stack gas were above 10.0 ng I-TEQ N m-3. The emission factors of PCDD/Fs from the investigated HWIs were in the range of 0.78-473.97 mu g I-TE ton(-1) medical wastes. It was estimated that 4.87 g I-TEQ of PCDD/Fs was annually released from HWIs to the atmosphere in China in 2006. Principal component analysis and hierarchical cluster analysis were applied to analyze the congener profiles of PCDD/Fs from HWIs in China. (C) 2009 Elsevier Ltd. All rights reserved.
Language英语
URL查看原文
WOS IDWOS:000271445700005
Citation statistics
Cited Times:45[WOS]   [WOS Record]     [Related Records in WOS]
Document Type期刊论文
Identifierhttp://cas-ir.dicp.ac.cn/handle/321008/102465
Collection中国科学院大连化学物理研究所
Corresponding AuthorChen JP(陈吉平)
Affiliation1.Chinese Acad Sci, Dalian Inst Chem Phys, Dalian 116023, Peoples R China
2.Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China
Recommended Citation
GB/T 7714
Gao, Hongcai,Ni, Yuwen,Zhang, Haijun,et al. Stack gas emissions of PCDD/Fs from hospital waste incinerators in China[J]. CHEMOSPHERE,2009,77(5):634-639.
APA Gao, Hongcai.,Ni, Yuwen.,Zhang, Haijun.,Zhao, Liang.,Zhang, Ning.,...&陈吉平.(2009).Stack gas emissions of PCDD/Fs from hospital waste incinerators in China.CHEMOSPHERE,77(5),634-639.
MLA Gao, Hongcai,et al."Stack gas emissions of PCDD/Fs from hospital waste incinerators in China".CHEMOSPHERE 77.5(2009):634-639.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Gao, Hongcai]'s Articles
[Ni, Yuwen]'s Articles
[Zhang, Haijun]'s Articles
Baidu academic
Similar articles in Baidu academic
[Gao, Hongcai]'s Articles
[Ni, Yuwen]'s Articles
[Zhang, Haijun]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Gao, Hongcai]'s Articles
[Ni, Yuwen]'s Articles
[Zhang, Haijun]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.