DICP OpenIR
Membrane affinity chromatography for analysis and purification of biopolymers
Zhou, DM; Zou, HF; Ni, JY; Wang, HL; Yang, L; Zhang, YK
KeywordColumn Liquid Chromatography Membrane Stationary Phase Immunoaffinity Analysis Affinity Efficiency Adsorption Capacity
Source PublicationCHROMATOGRAPHIA
1999-07-01
Volume50Issue:1-2Pages:27-34
Indexed BySCI
SubtypeArticle
WOS HeadingsScience & Technology ; Life Sciences & Biomedicine ; Physical Sciences
WOS SubjectBiochemical Research Methods ; Chemistry, Analytical
WOS Research AreaBiochemistry & Molecular Biology ; Chemistry
WOS KeywordBIOMOLECULES ; PERFORMANCE ; PROTEINS ; REMOVAL
AbstractAffinity columns suitable for HPLC were prepared by immobilization of various ligands of protein A, human IgG, human IgM and pectinase on GMA modified cellulose membrane. The adsorption capacity, affinity efficiency and activity recovery of various IgGs on these affinity columns were measured. It was observed that the length of the coupling arm plays a very important role in affinity efficiency, and the effect of eluent flow-rate on adsorption capacity was very small. The protein A column was exploited for the process monitoring of dog IgG in clinical experiments on immuno-adsorption therapy. A pectinase column was used for the determination of polygalacturonase inhibiting proteins first purified on a hydroxyapatite column. It took only about 2.5 min for analysis at a flow-rate of 1.0 mL min(-1). The high speed analysis of biopolymers could be performed at a flow rate of 6.0 mL min(-1) within 15 s. Membrane affinity chromatography gives good reproducibility, high efficiency, low column-pressure and is rapid. It can also be used for micro-scale purification of biopolymers.
Language英语
WOS IDWOS:000081720200006
Citation statistics
Cited Times:6[WOS]   [WOS Record]     [Related Records in WOS]
Document Type期刊论文
Identifierhttp://cas-ir.dicp.ac.cn/handle/321008/138576
Collection中国科学院大连化学物理研究所
AffiliationChinese Acad Sci, Dalian Inst Chem Phys, Natl Chromatog R&A Ctr, Dalian 116011, Peoples R China
Recommended Citation
GB/T 7714
Zhou, DM,Zou, HF,Ni, JY,et al. Membrane affinity chromatography for analysis and purification of biopolymers[J]. CHROMATOGRAPHIA,1999,50(1-2):27-34.
APA Zhou, DM,Zou, HF,Ni, JY,Wang, HL,Yang, L,&Zhang, YK.(1999).Membrane affinity chromatography for analysis and purification of biopolymers.CHROMATOGRAPHIA,50(1-2),27-34.
MLA Zhou, DM,et al."Membrane affinity chromatography for analysis and purification of biopolymers".CHROMATOGRAPHIA 50.1-2(1999):27-34.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Zhou, DM]'s Articles
[Zou, HF]'s Articles
[Ni, JY]'s Articles
Baidu academic
Similar articles in Baidu academic
[Zhou, DM]'s Articles
[Zou, HF]'s Articles
[Ni, JY]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Zhou, DM]'s Articles
[Zou, HF]'s Articles
[Ni, JY]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.