WOS KeywordDIKETONATE-EUROPIUM CHELATE ; CHROMATOGRAPHY-MASS-SPECTROMETRY ; TREATED SEWAGE EFFLUENT ; SOLID-PHASE EXTRACTION ; ESTROGENIC CHEMICALS ; AQUATIC ENVIRONMENT ; STW EFFLUENT ; LABEL ; IDENTIFICATION ; ESTRADIOL
AbstractA sensitive method for detecting 17beta-estradiol (E2) and estriol (E3) in river water has been developed, based on the time-resolved fluoroimmunoassay by using a fluorescent europium chelate label, 4,4'-bis(1",1",1",2",2",3",3"-heptafluoro-4",6"-hexanedion-6"-yl)-chlorosulfo-o-terphenyl (BHHCT)-Eu3+. In the E2 assay, microtiter plates were coated with the E2-bovine serum albumin (BSA) conjugate. The anti-17beta-estradiol antibody, the biotinylated goat anti-rabbit IgG antibody and the BHHCT-Eu3+ labeled streptavidin (SA)-BSA conjugate were used. In the E3 assay, the goat anti-rabbit IgG antibody was coated on a microtiter plate. The anti-estriol antibody and the BHHCT-Eu3+ labeled E3-BSA conjugate were used. The detection limits for E2 and E3 were 2.3 pg/ml and 4.3 pg/ml, respectively, and the analytical recoveries were 95-120%. Quantitative measurement of estrogens in river water was carried out for Kanda River (Tokyo, Japan) by using the method. The E2 and E3 levels were 32 pg/ml and 5.5 pg/ml, respectively. The detection limits of the present method are in the same orders of magnitude as those of ELISA for E2, and are 1-2 orders of magnitude better for E3.
Language英语
WOS IDWOS:000177500200002
Citation statistics
Cited Times:28[WOS]   [WOS Record]     [Related Records in WOS]
Document Type期刊论文
Identifierhttp://cas-ir.dicp.ac.cn/handle/321008/139086
Collection中国科学院大连化学物理研究所
Affiliation1.Waseda Univ, Adv Res Inst Sci & Engn, Dept Chem, Shinju Ku, Tokyo 1698555, Japan
2.Chinese Acad Sci, Dalian Inst Chem Phys, Dept Analyt Chem, Dalian 116012, Peoples R China
Recommended Citation
GB/T 7714
Majima, K,Fukui, T,Yuan, JL,et al. Quantitative measurement of 17 beta-estradiol and estriol in river water by time-resolved fluoroimmunoassay[J]. ANALYTICAL SCIENCES,2002,18(8):869-874.
APA Majima, K,Fukui, T,Yuan, JL,Wang, GL,&Matsumoto, K.(2002).Quantitative measurement of 17 beta-estradiol and estriol in river water by time-resolved fluoroimmunoassay.ANALYTICAL SCIENCES,18(8),869-874.
MLA Majima, K,et al."Quantitative measurement of 17 beta-estradiol and estriol in river water by time-resolved fluoroimmunoassay".ANALYTICAL SCIENCES 18.8(2002):869-874.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Majima, K]'s Articles
[Fukui, T]'s Articles
[Yuan, JL]'s Articles
Baidu academic
Similar articles in Baidu academic
[Majima, K]'s Articles
[Fukui, T]'s Articles
[Yuan, JL]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Majima, K]'s Articles
[Fukui, T]'s Articles
[Yuan, JL]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.