英文摘要: One-step extraction and high performance liquid chromatography (HPLC) with coulometric porous graphite electrode array detector method have been developed for the determination of ten sulfa drugs residues in chicken meat. The extraction recoveries of the ten sulfa drugs are higher than 50% with mixture of acetonitrile and chloroform ( acetonitrile : chloroform is 10:1). The redox characteristics of the ten sulfa drugs on porous graphite electrode have been studied, and then the potential for detecting the sulfa drugs is fixed on 455,560,630,670 and 710 mV on electrodes in series. The ten analytes have been separated very well on Hypersil BDS C-18 column with mobile phases containing acetonitrile and 30 mmol/L NaH2PO4 ( pH 5), and with a linear gradient eluting program of acetonitrile from 8. 5% to 37.5% ( V/V) in 40 minutes. The contaminant from chicken meat does not affect the separation of the ten sulfa drugs. The limit of detection is 40 mu g/kg for SIA and 20 mu g/kg for SA, SDZ, SMR, SMZ, SPD, STZ, SMTZ, SCP, and SMX in chicken meat. There are good linear correlations between the peak areas and concentrations of the ten sulfa drugs, the linear range is 0. 1 similar to 2. 0 mg/L and the correlation coefficients are above 0. 99. The electrode recovery is simple and can realize on-line cleanout. This method using HPLC-coulometric array detector is reproducible, and sensitive enough for the determination of sulfa drugs in chicken meat. It is easy to perform.
关键词[WOS]: AMPEROMETRIC DETECTION ;  SULFONAMIDES ;  HPLC ;  DERIVATIZATION ;  TISSUES
语种: 英语
WOS记录号: WOS:000228870200002
Citation statistics: 
内容类型: 期刊论文
URI标识: http://cas-ir.dicp.ac.cn/handle/321008/139699
Appears in Collections:中国科学院大连化学物理研究所_期刊论文

Files in This Item:

There are no files associated with this item.


作者单位: 1.Chinese Acad Sci, Dalian Inst Chem Phys, Dalian 116023, Peoples R China
2.Liaoning Normal Univ, Dalian 116029, Peoples R China

Recommended Citation:
Li, SG,Zhao, JM,Wang, WX,et al. Simultaneous determination of ten sulfa drugs in chicken meat by high performance liquid chromatography coulometric array detector[J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,2005,33(4):442-446.
Service
 Recommend this item
 Sava as my favorate item
 Show this item's statistics
 Export Endnote File
Google Scholar
 Similar articles in Google Scholar
 [Li, SG]'s Articles
 [Zhao, JM]'s Articles
 [Wang, WX]'s Articles
CSDL cross search
 Similar articles in CSDL Cross Search
 [Li, SG]‘s Articles
 [Zhao, JM]‘s Articles
 [Wang, WX]‘s Articles
Related Copyright Policies
Null
Social Bookmarking
  Add to CiteULike  Add to Connotea  Add to Del.icio.us  Add to Digg  Add to Reddit 
所有评论 (0)
暂无评论
 
评注功能仅针对注册用户开放,请您登录
您对该条目有什么异议,请填写以下表单,管理员会尽快联系您。
内 容:
Email:  *
单位:
验证码:   刷新
您在IR的使用过程中有什么好的想法或者建议可以反馈给我们。
标 题:
 *
内 容:
Email:  *
验证码:   刷新

Items in IR are protected by copyright, with all rights reserved, unless otherwise indicated.

 

 

Valid XHTML 1.0!
Powered by CSpace