Novel, fully automatic hydrophilic interaction/reversed-phase column-switching high-performance liquid chromatographic system for the complementary analysis of polar and apolar compounds in complex samples
Wang, Yuan1; Lehmann, Rainer2; Lu, Xin1; Zhao, Xinjie1; Xu, Guowang1
关键词Hplc Column-switching Hilic Hydrophobic Hydrophilic Metabonomics
刊名JOURNAL OF CHROMATOGRAPHY A
2008-09-12
DOI10.1016/j.chroma.2008.07.010
1204期:1页:28-34
收录类别SCI
文章类型Article
WOS标题词Science & Technology ; Life Sciences & Biomedicine ; Physical Sciences
类目[WOS]Biochemical Research Methods ; Chemistry, Analytical
研究领域[WOS]Biochemistry & Molecular Biology ; Chemistry
关键词[WOS]TANDEM MASS-SPECTROMETRY ; COMPREHENSIVE 2-DIMENSIONAL SEPARATIONS ; REVERSED-PHASE ; FLUORESCENCE DETECTION ; MICRODIALYSIS SAMPLES ; PEAK-CAPACITY ; HUMAN PLASMA ; MS METHOD ; ESI-MS ; HPLC
英文摘要in this study we developed and optimized a column-switching high-performance liquid chromatographic (HPLC) system for the complementary analysis of polar and apolar compounds in complex samples. The polar compounds are separated on a hydrophilic interaction chromatographic (HILIC) column; the part of the sample non-retained on HILIC is transferred into and separated on a reversed-phase (RP) column through an interface, thus preventing the loss of analytes eluting at dead time in common single-column mode. The signals are in turn recorded in the same chromatogram either by a UV or by a mass spectrometric detector. Applying a mixture of 25 standard compounds (12 hydrophilic and 13 hydrophobic) the system proves to be reliable, robust and easy-operating. The investigation of urine revealed an increase in the detected metabolite ion masses compared to the single-column HILIC-electrospray ionization (ESI)-MS analysis. Utilizing online the complementary selectivity of HILIC and RPLC in a fully automatic mode, this approach holds out the prospect to enlarge the number of detectable compounds in non-targeted "-omics" studies and sophisticated target-driven approaches by a single injection. (c) 2008 Elsevier B.V. All rights reserved.
语种英语
WOS记录号WOS:000259516400004
引用统计
文献类型期刊论文
条目标识符http://cas-ir.dicp.ac.cn/handle/321008/141071
专题中国科学院大连化学物理研究所
作者单位1.Chinese Acad Sci, Dalian Inst Chem Phys, Natl Chromatog R&A Ctr, Dalian 116023, Peoples R China
2.Univ Hosp Tuebingen, Dept Internal Med 4, Cent Lab, Div Clin Chem & Pathobiochem, D-72076 Tubingen, Germany
推荐引用方式
GB/T 7714
Wang, Yuan,Lehmann, Rainer,Lu, Xin,et al. Novel, fully automatic hydrophilic interaction/reversed-phase column-switching high-performance liquid chromatographic system for the complementary analysis of polar and apolar compounds in complex samples[J]. JOURNAL OF CHROMATOGRAPHY A,2008,1204(1):28-34.
APA Wang, Yuan,Lehmann, Rainer,Lu, Xin,Zhao, Xinjie,&Xu, Guowang.(2008).Novel, fully automatic hydrophilic interaction/reversed-phase column-switching high-performance liquid chromatographic system for the complementary analysis of polar and apolar compounds in complex samples.JOURNAL OF CHROMATOGRAPHY A,1204(1),28-34.
MLA Wang, Yuan,et al."Novel, fully automatic hydrophilic interaction/reversed-phase column-switching high-performance liquid chromatographic system for the complementary analysis of polar and apolar compounds in complex samples".JOURNAL OF CHROMATOGRAPHY A 1204.1(2008):28-34.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Wang, Yuan]的文章
[Lehmann, Rainer]的文章
[Lu, Xin]的文章
百度学术
百度学术中相似的文章
[Wang, Yuan]的文章
[Lehmann, Rainer]的文章
[Lu, Xin]的文章
必应学术
必应学术中相似的文章
[Wang, Yuan]的文章
[Lehmann, Rainer]的文章
[Lu, Xin]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。