题名: A novel approach to transforming a non-targeted metabolic profiling method to a pseudo-targeted method using the retention time locking gas chromatography/mass spectrometry-selected ions monitoring
作者: Li, Yong1;  Ruan, Qiang2;  Li, Yanli1;  Ye, Guozhu1;  Lu, Xin1;  Lin, Xiaohui2;  Xu, Guowang1
关键词: Retention time locking ;  Gas chromatography/mass spectrometry ;  Metabolic profiling ;  Full scan ;  Selected ion monitoring
刊名: JOURNAL OF CHROMATOGRAPHY A
发表日期: 2012-09-14
DOI: 10.1016/j.chroma.2012.01.076
卷: 1255, 页:228-236
收录类别: SCI
文章类型: Article
WOS标题词: Science & Technology ;  Life Sciences & Biomedicine ;  Physical Sciences
类目[WOS]: Biochemical Research Methods ;  Chemistry, Analytical
研究领域[WOS]: Biochemistry & Molecular Biology ;  Chemistry
英文摘要: Non-targeted metabolic profiling is the most widely used method for metabolomics. In this paper, a novel approach was established to transform a non-targeted metabolic profiling method to a pseudo-targeted method using the retention time locking gas chromatography/mass spectrometry-selected ion monitoring (RTL-GC/MS-SIM). To achieve this transformation, an algorithm based on the automated mass spectral deconvolution and identification system (AMDIS), GC/MS raw data and a bi-Gaussian chromatographic peak model was developed. The established GC/MS-SIM method was compared with GC/MS-full scan (the total ion current and extracted ion current, TIC and EIC) methods, it was found that for a typical tobacco leaf extract, 93% components had their relative standard deviations (RSDs) of relative peak areas less than 20% by the SIM method, while 88% by the EIC method and 81% by the TIC method. 47.3% components had their linear correlation coefficient higher than 0.99, compared with 5.0% by the EIC and 6.2% by TIC methods. Multivariate analysis showed the pooled quality control samples clustered more tightly using the developed method than using GC/MS-full scan methods, indicating a better data quality. With the analysis of the variance of the tobacco samples from three different planting regions, 167 differential components (p < 0.05) were screened out using the RTL-GC/MS-SIM method, but 151 and 131 by the EIC and TIC methods, respectively. The results show that the developed method not only has a higher sensitivity, better linearity and data quality, but also does not need complicated peak alignment among different samples. It is especially suitable for the screening of differential components in the metabolic profiling investigation. (C) 2012 Elsevier B.V. All rights reserved.
关键词[WOS]: FLIGHT MASS-SPECTROMETRY ;  PESTICIDE-RESIDUE ANALYSIS ;  BIOMARKER DISCOVERY ;  GC-MS ;  SCAN ;  FOOD ;  QUANTIFICATION ;  IDENTIFICATION ;  ADVANTAGES ;  GENOMICS
语种: 英语
WOS记录号: WOS:000308524600023
Citation statistics: 
内容类型: 期刊论文
URI标识: http://cas-ir.dicp.ac.cn/handle/321008/142964
Appears in Collections:中国科学院大连化学物理研究所_期刊论文

Files in This Item:

There are no files associated with this item.


作者单位: 1.Chinese Acad Sci, Dalian Inst Chem Phys, CAS Key Lab Separat Sci Analyt Chem, Dalian 116023, Peoples R China
2.Dalian Univ Technol, Sch Comp Sci & Technol, Dept Comp Sci &Engn, Dalian 116024, Peoples R China

Recommended Citation:
Li, Yong,Ruan, Qiang,Li, Yanli,et al. A novel approach to transforming a non-targeted metabolic profiling method to a pseudo-targeted method using the retention time locking gas chromatography/mass spectrometry-selected ions monitoring[J]. JOURNAL OF CHROMATOGRAPHY A,2012,1255:228-236.
Service
 Recommend this item
 Sava as my favorate item
 Show this item's statistics
 Export Endnote File
Google Scholar
 Similar articles in Google Scholar
 [Li, Yong]'s Articles
 [Ruan, Qiang]'s Articles
 [Li, Yanli]'s Articles
CSDL cross search
 Similar articles in CSDL Cross Search
 [Li, Yong]‘s Articles
 [Ruan, Qiang]‘s Articles
 [Li, Yanli]‘s Articles
Related Copyright Policies
Null
Social Bookmarking
  Add to CiteULike  Add to Connotea  Add to Del.icio.us  Add to Digg  Add to Reddit 
所有评论 (0)
暂无评论
 
评注功能仅针对注册用户开放,请您登录
您对该条目有什么异议,请填写以下表单,管理员会尽快联系您。
内 容:
Email:  *
单位:
验证码:   刷新
您在IR的使用过程中有什么好的想法或者建议可以反馈给我们。
标 题:
 *
内 容:
Email:  *
验证码:   刷新

Items in IR are protected by copyright, with all rights reserved, unless otherwise indicated.

 

 

Valid XHTML 1.0!
Powered by CSpace