DICP OpenIR
A twisted-intramolecular-charge-transfer (TICT) based ratiometric fluorescent thermometer with a mega-Stokes shift and a positive temperature coefficient
Cao, Cheng1,2; Liu, Xiaogang2,3; Qiao, Qinglong2; Zhao, Miao2; Yin, Wenting2; Mao, Deqi2; Zhang, Hui1; Xu, Zhaochao2
刊名CHEMICAL COMMUNICATIONS
2014
DOI10.1039/c4cc08010f
50期:99页:15811-15814
收录类别SCI ; IC
文章类型Article
WOS标题词Science & Technology ; Physical Sciences
类目[WOS]Chemistry, Multidisciplinary
研究领域[WOS]Chemistry
关键词[WOS]MICROFLUIDIC DEVICES ; LIVING CELLS ; LIVE CELLS ; SENSOR ; RANGE ; POLYMER ; PROBES ; DOTS ; DYES ; FILM
英文摘要The fluorescence intensity of N, N-dimethyl-4-((2-methylquinolin-6-yl)ethynyl) aniline exhibits an unusual intensification with increasing temperature, by activating more vibrational bands and leading to stronger TICT emissions upon heating in dimethyl sulfoxide. Based on the different temperature dependence at various wavelengths, as shown in the TICT fluorescence spectrum, this dye can be employed to ratiometrically detect temperature.
语种英语
WOS记录号WOS:000345305600039
引用统计
文献类型期刊论文
条目标识符http://cas-ir.dicp.ac.cn/handle/321008/143167
专题中国科学院大连化学物理研究所
作者单位1.Shenyang Pharmaceut Univ, Sch Pharmaceut Engn, Shenyang 110016, Peoples R China
2.Chinese Acad Sci, Dalian Inst Chem Phys, Key Lab Separat Sci Analyt Chem, Dalian 116023, Peoples R China
3.Singapore MIT Alliance Res & Technol SMART Ctr, Singapore 138602, Singapore
推荐引用方式
GB/T 7714
Cao, Cheng,Liu, Xiaogang,Qiao, Qinglong,et al. A twisted-intramolecular-charge-transfer (TICT) based ratiometric fluorescent thermometer with a mega-Stokes shift and a positive temperature coefficient[J]. CHEMICAL COMMUNICATIONS,2014,50(99):15811-15814.
APA Cao, Cheng.,Liu, Xiaogang.,Qiao, Qinglong.,Zhao, Miao.,Yin, Wenting.,...&Xu, Zhaochao.(2014).A twisted-intramolecular-charge-transfer (TICT) based ratiometric fluorescent thermometer with a mega-Stokes shift and a positive temperature coefficient.CHEMICAL COMMUNICATIONS,50(99),15811-15814.
MLA Cao, Cheng,et al."A twisted-intramolecular-charge-transfer (TICT) based ratiometric fluorescent thermometer with a mega-Stokes shift and a positive temperature coefficient".CHEMICAL COMMUNICATIONS 50.99(2014):15811-15814.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Cao, Cheng]的文章
[Liu, Xiaogang]的文章
[Qiao, Qinglong]的文章
百度学术
百度学术中相似的文章
[Cao, Cheng]的文章
[Liu, Xiaogang]的文章
[Qiao, Qinglong]的文章
必应学术
必应学术中相似的文章
[Cao, Cheng]的文章
[Liu, Xiaogang]的文章
[Qiao, Qinglong]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。