DICP OpenIR
A twisted-intramolecular-charge-transfer (TICT) based ratiometric fluorescent thermometer with a mega-Stokes shift and a positive temperature coefficient
Cao, Cheng1,2; Liu, Xiaogang2,3; Qiao, Qinglong2; Zhao, Miao2; Yin, Wenting2; Mao, Deqi2; Zhang, Hui1; Xu, Zhaochao2
Source PublicationCHEMICAL COMMUNICATIONS
2014
DOI10.1039/c4cc08010f
Volume50Issue:99Pages:15811-15814
Indexed BySCI ; IC
SubtypeArticle
WOS HeadingsScience & Technology ; Physical Sciences
WOS SubjectChemistry, Multidisciplinary
WOS Research AreaChemistry
WOS KeywordMICROFLUIDIC DEVICES ; LIVING CELLS ; LIVE CELLS ; SENSOR ; RANGE ; POLYMER ; PROBES ; DOTS ; DYES ; FILM
AbstractThe fluorescence intensity of N, N-dimethyl-4-((2-methylquinolin-6-yl)ethynyl) aniline exhibits an unusual intensification with increasing temperature, by activating more vibrational bands and leading to stronger TICT emissions upon heating in dimethyl sulfoxide. Based on the different temperature dependence at various wavelengths, as shown in the TICT fluorescence spectrum, this dye can be employed to ratiometrically detect temperature.
Language英语
WOS IDWOS:000345305600039
Citation statistics
Cited Times:62[WOS]   [WOS Record]     [Related Records in WOS]
Document Type期刊论文
Identifierhttp://cas-ir.dicp.ac.cn/handle/321008/143167
Collection中国科学院大连化学物理研究所
Affiliation1.Shenyang Pharmaceut Univ, Sch Pharmaceut Engn, Shenyang 110016, Peoples R China
2.Chinese Acad Sci, Dalian Inst Chem Phys, Key Lab Separat Sci Analyt Chem, Dalian 116023, Peoples R China
3.Singapore MIT Alliance Res & Technol SMART Ctr, Singapore 138602, Singapore
Recommended Citation
GB/T 7714
Cao, Cheng,Liu, Xiaogang,Qiao, Qinglong,et al. A twisted-intramolecular-charge-transfer (TICT) based ratiometric fluorescent thermometer with a mega-Stokes shift and a positive temperature coefficient[J]. CHEMICAL COMMUNICATIONS,2014,50(99):15811-15814.
APA Cao, Cheng.,Liu, Xiaogang.,Qiao, Qinglong.,Zhao, Miao.,Yin, Wenting.,...&Xu, Zhaochao.(2014).A twisted-intramolecular-charge-transfer (TICT) based ratiometric fluorescent thermometer with a mega-Stokes shift and a positive temperature coefficient.CHEMICAL COMMUNICATIONS,50(99),15811-15814.
MLA Cao, Cheng,et al."A twisted-intramolecular-charge-transfer (TICT) based ratiometric fluorescent thermometer with a mega-Stokes shift and a positive temperature coefficient".CHEMICAL COMMUNICATIONS 50.99(2014):15811-15814.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Cao, Cheng]'s Articles
[Liu, Xiaogang]'s Articles
[Qiao, Qinglong]'s Articles
Baidu academic
Similar articles in Baidu academic
[Cao, Cheng]'s Articles
[Liu, Xiaogang]'s Articles
[Qiao, Qinglong]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Cao, Cheng]'s Articles
[Liu, Xiaogang]'s Articles
[Qiao, Qinglong]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.