DICP OpenIR
Coumarin 545: an emission reference dye with a record-low temperature coefficient for ratiometric fluorescence based temperature measurements
Mao, Deqi1,2; Liu, Xiaogang3; Qiao, Qinglong1,2; Yin, Wenting2; Zhao, Miao2; Cole, Jacqueline M.3,4; Cui, Jingnan1; Xu, Zhaochao1,2
Source PublicationANALYST
2015
DOI10.1039/c4an02075h
Volume140Issue:4Pages:1008-1013
Indexed BySCI
SubtypeArticle
WOS HeadingsScience & Technology ; Physical Sciences
WOS SubjectChemistry, Analytical
WOS Research AreaChemistry
WOS KeywordMICROFLUIDIC DEVICES ; LIVING CELLS ; THERMOMETER ; SENSOR ; RANGE ; AGGREGATION ; POLYMER ; PROBES ; FILM
AbstractThe emission intensities of coumarin 545 solution exhibit a low temperature dependence, with a record-low temperature coefficient of only similar to 0.025% per degrees C. This monomer-aggregate coupled fluorescence system can be used for ratiometric temperature measurements with high spatial and temporal resolutions; three different working modes have been demonstrated.
Language英语
WOS IDWOS:000349362700007
Citation statistics
Document Type期刊论文
Identifierhttp://cas-ir.dicp.ac.cn/handle/321008/145972
Collection中国科学院大连化学物理研究所
Affiliation1.Dalian Univ Technol, State Key Lab Fine Chem, Dalian 116012, Peoples R China
2.Chinese Acad Sci, Dalian Inst Chem Phys, Key Lab Separat Sci Analyt Chem, Dalian 116023, Peoples R China
3.Univ Cambridge, Cavendish Lab, Dept Phys, Cambridge CB3 0HE, England
4.Argonne Natl Lab, Argonne, IL 60439 USA
Recommended Citation
GB/T 7714
Mao, Deqi,Liu, Xiaogang,Qiao, Qinglong,et al. Coumarin 545: an emission reference dye with a record-low temperature coefficient for ratiometric fluorescence based temperature measurements[J]. ANALYST,2015,140(4):1008-1013.
APA Mao, Deqi.,Liu, Xiaogang.,Qiao, Qinglong.,Yin, Wenting.,Zhao, Miao.,...&Xu, Zhaochao.(2015).Coumarin 545: an emission reference dye with a record-low temperature coefficient for ratiometric fluorescence based temperature measurements.ANALYST,140(4),1008-1013.
MLA Mao, Deqi,et al."Coumarin 545: an emission reference dye with a record-low temperature coefficient for ratiometric fluorescence based temperature measurements".ANALYST 140.4(2015):1008-1013.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Mao, Deqi]'s Articles
[Liu, Xiaogang]'s Articles
[Qiao, Qinglong]'s Articles
Baidu academic
Similar articles in Baidu academic
[Mao, Deqi]'s Articles
[Liu, Xiaogang]'s Articles
[Qiao, Qinglong]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Mao, Deqi]'s Articles
[Liu, Xiaogang]'s Articles
[Qiao, Qinglong]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.