题名: Dopant titrating ion mobility spectrometry for trace exhaled nitric oxide detection
作者: Peng, Liying1, 3;  Hua, Lei1;  Li, Enyou2;  Wang, Weiguo1;  Zhou, Qinghua1, 3;  Wang, Xin1;  Wang, Changsong2;  Li, Jinghua1;  Li, Haiyang1
关键词: ion mobility spectrometry ;  exhaled nitric oxide ;  breath gas ;  dopant
刊名: JOURNAL OF BREATH RESEARCH
发表日期: 2015-03-01
DOI: 10.1088/1752-7155/9/1/016003
卷: 9, 期:1
收录类别: SCI
文章类型: Article
WOS标题词: Science & Technology ;  Life Sciences & Biomedicine
类目[WOS]: Biochemical Research Methods ;  Respiratory System
研究领域[WOS]: Biochemistry & Molecular Biology ;  Respiratory System
英文摘要: Ion mobility spectrometry (IMS) is a promising non-invasive tool for the analysis of exhaled gas and exhaled nitric oxide (NO), a biomarker for diagnosis of respiratory diseases. However, the high moisture in exhaled gas always brings about extra overlapping ion peaks and results in poor identification ability. In this paper, p-benzoquinone (PBQ) was introduced into IMS to eliminate the interference of overlapping ion peaks and realize the selective identification of NO. The overlapping ions caused by moisture were titrated by PBQ and then converted to hydrated PBQ anions (C6H4O2-(H2O)(n)). The NO concentration could be determined by quantifying gas phase hydrated nitrite anions (NO2-(H2O)(n)), product ions of NO. Under optimized conditions, a limit of detection (LOD) of about 1.4 ppbv and a linear range of 10-200 ppbv were obtained for NO even in 100% relative humidity (RH) purified air. Furthermore, this established method was applied to measure hourly the exhaled NO of eight healthy volunteers, and real-time monitoring the exhaled NO of an esophageal carcinoma patient during radical surgery. These results revealed the potential of the current dopant titrating IMS method in the measurement of exhaled NO for medical disease diagnosis.
关键词[WOS]: MASS-SPECTROMETRY ;  CORONA DISCHARGE ;  BREATH ;  AIR ;  MIXTURES ;  SERIES ;  GASES ;  MEDIA ;  IMS
语种: 英语
WOS记录号: WOS:000351955400004
Citation statistics: 
内容类型: 期刊论文
URI标识: http://cas-ir.dicp.ac.cn/handle/321008/146117
Appears in Collections:中国科学院大连化学物理研究所_期刊论文

Files in This Item:

There are no files associated with this item.


作者单位: 1.Chinese Acad Sci, Dalian Inst Chem Phys, Key Lab Separat Sci Analyt Chem, Dalian 116023, Peoples R China
2.Harbin Med Univ, Dept Anesthesiol, Affiliated Hosp 1, Harbin 150001, Heilongjiang, Peoples R China
3.Univ Chinese Acad Sci, Beijing 100049, Peoples R China

Recommended Citation:
Peng, Liying,Hua, Lei,Li, Enyou,et al. Dopant titrating ion mobility spectrometry for trace exhaled nitric oxide detection[J]. JOURNAL OF BREATH RESEARCH,2015,9(1).
Service
 Recommend this item
 Sava as my favorate item
 Show this item's statistics
 Export Endnote File
Google Scholar
 Similar articles in Google Scholar
 [Peng, Liying]'s Articles
 [Hua, Lei]'s Articles
 [Li, Enyou]'s Articles
CSDL cross search
 Similar articles in CSDL Cross Search
 [Peng, Liying]‘s Articles
 [Hua, Lei]‘s Articles
 [Li, Enyou]‘s Articles
Related Copyright Policies
Null
Social Bookmarking
  Add to CiteULike  Add to Connotea  Add to Del.icio.us  Add to Digg  Add to Reddit 
所有评论 (0)
暂无评论
 
评注功能仅针对注册用户开放,请您登录
您对该条目有什么异议,请填写以下表单,管理员会尽快联系您。
内 容:
Email:  *
单位:
验证码:   刷新
您在IR的使用过程中有什么好的想法或者建议可以反馈给我们。
标 题:
 *
内 容:
Email:  *
验证码:   刷新

Items in IR are protected by copyright, with all rights reserved, unless otherwise indicated.

 

 

Valid XHTML 1.0!
Powered by CSpace