Time-resolved dynamic dilution introduction for ion mobility spectrometry and its application in end-tidal propofol monitoring
Zhou, Qinghua1,3; Li, Enyou2; Wang, Zhenxin1; Gong, Yulei2; Wang, Changsong2; Guo, Lei2; Li, Haiyang1
关键词Time-resolved Dynamic Dilution Introduction Ion Mobility Spectrometry Propofol
刊名JOURNAL OF BREATH RESEARCH
2015-03-01
DOI10.1088/1752-7155/9/1/016002
9期:1
收录类别SCI
文章类型Article
WOS标题词Science & Technology ; Life Sciences & Biomedicine
类目[WOS]Biochemical Research Methods ; Respiratory System
研究领域[WOS]Biochemistry & Molecular Biology ; Respiratory System
关键词[WOS]TOTAL INTRAVENOUS ANESTHESIA ; SENSITIVE DETECTION ; ONLINE MEASUREMENT ; MASS-SPECTROMETRY ; HUMAN BREATH ; EXHALED AIR ; GAS ; EXPLOSIVES ; FEASIBILITY ; METABOLITES
英文摘要Based on the adsorption of analytes in the sampling loop, a time-resolved dynamic dilution introduction method was developed for negative ion mobility spectrometry to continuously monitor end-tidal propofol without other sample pre-separation. The dynamic dilution characteristics of propofol and moisture in the Teflon sample loop (4 mm o. d. and 2.4 mm i. d., 150 cm length) were both theoretically and experimentally investigated. The prominent absorption differences between propofol and moisture on the inwall of the sample loop allowed their concentrations to be time-resolved during the injection process, realizing sensitive measurement of end-tidal propofol with a response time of 2 s. At the optimized carrier gas flow rate of 700 mL min(-1), the linear response range for propofol was achieved to be 0.2 to 20 ppbv with a limit of detection (LOD) of 65 pptv. Finally, this method was performed on a patient undergoing mastectomy surgery to continuously monitor the end-tidal propofol with an interval of five respirations and the result nicely demonstrated its fast response to the propofol changes.
语种英语
WOS记录号WOS:000351955400003
引用统计
文献类型期刊论文
条目标识符http://cas-ir.dicp.ac.cn/handle/321008/146120
专题中国科学院大连化学物理研究所
作者单位1.Chinese Acad Sci, Dalian Inst Chem Phys, Key Lab Separat Sci Analyt Chem, Dalian 116023, Liaoning, Peoples R China
2.Harbin Med Univ, Dept Anesthesiol, Affiliated Hosp 1, Harbin 150001, Heilongjiang, Peoples R China
3.Univ Chinese Acad Sci, Beijing 100049, Peoples R China
推荐引用方式
GB/T 7714
Zhou, Qinghua,Li, Enyou,Wang, Zhenxin,et al. Time-resolved dynamic dilution introduction for ion mobility spectrometry and its application in end-tidal propofol monitoring[J]. JOURNAL OF BREATH RESEARCH,2015,9(1).
APA Zhou, Qinghua.,Li, Enyou.,Wang, Zhenxin.,Gong, Yulei.,Wang, Changsong.,...&Li, Haiyang.(2015).Time-resolved dynamic dilution introduction for ion mobility spectrometry and its application in end-tidal propofol monitoring.JOURNAL OF BREATH RESEARCH,9(1).
MLA Zhou, Qinghua,et al."Time-resolved dynamic dilution introduction for ion mobility spectrometry and its application in end-tidal propofol monitoring".JOURNAL OF BREATH RESEARCH 9.1(2015).
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Zhou, Qinghua]的文章
[Li, Enyou]的文章
[Wang, Zhenxin]的文章
百度学术
百度学术中相似的文章
[Zhou, Qinghua]的文章
[Li, Enyou]的文章
[Wang, Zhenxin]的文章
必应学术
必应学术中相似的文章
[Zhou, Qinghua]的文章
[Li, Enyou]的文章
[Wang, Zhenxin]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。