DICP OpenIR
Determination of Polychlorinated Dibenzo-p-dioxins/Dibenzofurans, Dioxin Like Polychlorinated Biphenyls, Brominated Flame Retardants and Polybrominated Dibenzo-p-dioxins/Dibenzofurans in Flue Gas from Stationary Source
Xu Peng-Jun1,2; Tao Bu3; Li Nan2; Zheng Sen2; Zhao Hu2; Fan Shuang2; Zhou Zhi-Guang2; Ren Yue2; Qi Li2; Chen Ji-Ping1
关键词Flue Gas Polychlorinated Dibenzo-p-Dioxins/dibenzofurans And Dioxin Like Polychlorinated Biphenyls Brominated Flame Retardants Polybrominated Dibenzo-p-dioxins/dibenzofurans Active Carbon-dispersed Silica Gel Reversal Elution
刊名CHINESE JOURNAL OF ANALYTICAL CHEMISTRY
2015-03-01
43期:3页:356-365
收录类别SCI
文章类型Article
WOS标题词Science & Technology ; Physical Sciences
类目[WOS]Chemistry, Analytical
研究领域[WOS]Chemistry
关键词[WOS]RESOLUTION MASS-SPECTROMETRY ; DIPHENYL ETHERS ; AMBIENT AIR ; SAMPLES ; PBDD/FS ; COLUMN
英文摘要A method for simultaneous determination of PCDDs, dl-PCBs, BFRs and PBDD/Fs in flue gas from stationary source was developed. The sample was extracted by Soxhlet apparatus with toluene, and followed by purification through sulfuric acid partition and multi. layer silica gel column separation. The target compounds were then all separated by passing through the active carbon. dispersed silica gel column and reversal eluting. Gas chromatography coupled with a thermostable capillary column (short length, thin stationary phase film) was operated at pulse injection mode. High resolution mass spectrometry set at low-electron-energy ionization was used for quantification. The high- and low-brominated compounds were determined simultaneously. The detection limits of this method were 0. 081 - 1. 2 pg for PCDD/Fs, 0. 100 - 32 pg for dl-PCBs, 0. 14 - 12 pg for PBDEs, 0. 26 - 16 pg for new BFRs, 0. 44 - 3. 6 pg for tetra- to hepta-BDD/Fs and 8. 2 - 12 pg for OBDD/F. Recoveries (RSDs) in spiked flue gas samples were 88% - 115% (2. 9% - 6. 1%) for PCDD/Fs, 84% - 118% (3. 2% - 10%) for dl-PCBs, 71% - 135% (2. 1% - 18%) for PBDEs, 71% - 114% (2. 9% - 7. 4%) for new BFRs, 83% - 127% (5. 2% - 10%) for tetra- to hepta. BDD/Fs and 52% - 149% (23% - 24%) for OBDD/F. All quality control data fell within the acceptable range specified in analysis standards for flue gas.
语种英语
WOS记录号WOS:000354901600005
引用统计
被引频次:3[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://cas-ir.dicp.ac.cn/handle/321008/146245
专题中国科学院大连化学物理研究所
作者单位1.Chinese Acad Sci, Dalian Inst Chem Phys, Dalian 116023, Peoples R China
2.Natl Res Ctr Environm Anal & Measurement, Beijing 100029, Peoples R China
3.Agr Univ Hebei, Baoding 071001, Peoples R China
推荐引用方式
GB/T 7714
Xu Peng-Jun,Tao Bu,Li Nan,et al. Determination of Polychlorinated Dibenzo-p-dioxins/Dibenzofurans, Dioxin Like Polychlorinated Biphenyls, Brominated Flame Retardants and Polybrominated Dibenzo-p-dioxins/Dibenzofurans in Flue Gas from Stationary Source[J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,2015,43(3):356-365.
APA Xu Peng-Jun.,Tao Bu.,Li Nan.,Zheng Sen.,Zhao Hu.,...&Chen Ji-Ping.(2015).Determination of Polychlorinated Dibenzo-p-dioxins/Dibenzofurans, Dioxin Like Polychlorinated Biphenyls, Brominated Flame Retardants and Polybrominated Dibenzo-p-dioxins/Dibenzofurans in Flue Gas from Stationary Source.CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,43(3),356-365.
MLA Xu Peng-Jun,et al."Determination of Polychlorinated Dibenzo-p-dioxins/Dibenzofurans, Dioxin Like Polychlorinated Biphenyls, Brominated Flame Retardants and Polybrominated Dibenzo-p-dioxins/Dibenzofurans in Flue Gas from Stationary Source".CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 43.3(2015):356-365.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Xu Peng-Jun]的文章
[Tao Bu]的文章
[Li Nan]的文章
百度学术
百度学术中相似的文章
[Xu Peng-Jun]的文章
[Tao Bu]的文章
[Li Nan]的文章
必应学术
必应学术中相似的文章
[Xu Peng-Jun]的文章
[Tao Bu]的文章
[Li Nan]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。