DICP OpenIR
Removal of endotoxin from human serum albumin solutions by hydrophobic and cationic charged membrane; Removal of endotoxin from human serum albumin solutions by hydrophobic and cationic charged membrane
Wei, GL; Shang, ZH; Pan, MC; Gao, ZH
关键词Hydrophobic And Cationic Charged Membrane Hydrophobic And Cationic Charged Membrane Endotoxin Removal Endotoxin Removal
刊名CHINESE CHEMICAL LETTERS ; CHINESE CHEMICAL LETTERS
2000-04-01 ; 2000-04-01
11期:4页:357-360
收录类别SCI ; SCI
文章类型Article ; Article
部门归属1 ; 1
项目归属102 ; 102
WOS标题词Science & Technology ; Science & Technology ; Physical Sciences ; Physical Sciences
类目[WOS]Chemistry, Multidisciplinary ; Chemistry, Multidisciplinary
研究领域[WOS]Chemistry ; Chemistry
英文摘要A novel matrix of macropore cellulose membrane was prepared by chemical graft, and immobilized the cationic charged groups as affinity ligands. The prepared membrane Fan be used for the removal of endotoxin from human serum albumin (HSA) solutions. With a cartridge of 20 sheets affinity membrane of 47 mm diameter, the endotoxin level in HSA solution can be reduced ro 0.027 eu/mL. Recovery of HSA was over 95%.; A novel matrix of macropore cellulose membrane was prepared by chemical graft, and immobilized the cationic charged groups as affinity ligands. The prepared membrane Fan be used for the removal of endotoxin from human serum albumin (HSA) solutions. With a cartridge of 20 sheets affinity membrane of 47 mm diameter, the endotoxin level in HSA solution can be reduced ro 0.027 eu/mL. Recovery of HSA was over 95%.
语种英语 ; 英语
原文出处查看原文 ; 查看原文
WOS记录号WOS:000086121800024 ; WOS:000086121800024
引用统计
被引频次:2[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://cas-ir.dicp.ac.cn/handle/321008/84713
专题中国科学院大连化学物理研究所
作者单位1.Chinese Acad Sci, Dalian Inst Chem Phys, Dalian 116012, Peoples R China
2.Dalian Med Univ, Teaching Hosp 1, Dalian, Peoples R China
推荐引用方式
GB/T 7714
Wei, GL,Shang, ZH,Pan, MC,et al. Removal of endotoxin from human serum albumin solutions by hydrophobic and cationic charged membrane, Removal of endotoxin from human serum albumin solutions by hydrophobic and cationic charged membrane[J]. CHINESE CHEMICAL LETTERS, CHINESE CHEMICAL LETTERS,2000, 2000,11, 11(4):357-360, 357-360.
APA Wei, GL,Shang, ZH,Pan, MC,&Gao, ZH.(2000).Removal of endotoxin from human serum albumin solutions by hydrophobic and cationic charged membrane.CHINESE CHEMICAL LETTERS,11(4),357-360.
MLA Wei, GL,et al."Removal of endotoxin from human serum albumin solutions by hydrophobic and cationic charged membrane".CHINESE CHEMICAL LETTERS 11.4(2000):357-360.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
200070PMC41N72.pdf(245KB) 开放获取--请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Wei, GL]的文章
[Shang, ZH]的文章
[Pan, MC]的文章
百度学术
百度学术中相似的文章
[Wei, GL]的文章
[Shang, ZH]的文章
[Pan, MC]的文章
必应学术
必应学术中相似的文章
[Wei, GL]的文章
[Shang, ZH]的文章
[Pan, MC]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。