DICP OpenIR
An integrated light emitting diode-induced fluorescence detector for capillary electrophoresis
Yang, BC; Tian, HZ; Xu, J; Guan, YF; Guan YF(关亚风); Guan YF(关亚风)
KeywordLight Emitting Diode Fluorescence Detection Capillary Electrophoresis
Source PublicationTALANTA
2006-06-15
DOI10.1016/j.talanta.2005.12.005
Volume69Issue:4Pages:996-1000
Indexed BySCI
SubtypeArticle
Department1
Funding Project105
Contribution Rank1;1
WOS HeadingsScience & Technology ; Physical Sciences
WOS SubjectChemistry, Analytical
WOS Research AreaChemistry
WOS KeywordWAVE-GUIDE ; LUMINESCENCE ; SYSTEM
AbstractAn integrated light emitting diode (LED)-induced fluorescence detector was described and evaluated. The LED and its related components including lens and interference filter, the optical fiber used to collect fluorescence, and the capillary column are integrated into a substrate block, which eliminates the need of align procedure of the fiber and the capillary. Forty-fold enhancement of sensitivity was obtained compared with our previous work and the detection limit for fluorescein was 5 nM. Application of the detector for the analysis of FITC-labeled Ephedrine extract was demonstrated. (c) 2005 Elsevier B.V. All rights reserved.
Language英语
URL查看原文
WOS IDWOS:000238303700033
Citation statistics
Cited Times:19[WOS]   [WOS Record]     [Related Records in WOS]
Document Type期刊论文
Identifierhttp://cas-ir.dicp.ac.cn/handle/321008/97633
Collection中国科学院大连化学物理研究所
Corresponding AuthorGuan YF(关亚风); Guan YF(关亚风)
AffiliationChinese Acad Sci, Dalian Inst Chem Phys, Dept Analyt Chem & Microinstrumentat, Dalian 116023, Peoples R China
Recommended Citation
GB/T 7714
Yang, BC,Tian, HZ,Xu, J,et al. An integrated light emitting diode-induced fluorescence detector for capillary electrophoresis[J]. TALANTA,2006,69(4):996-1000.
APA Yang, BC,Tian, HZ,Xu, J,Guan, YF,关亚风,&关亚风.(2006).An integrated light emitting diode-induced fluorescence detector for capillary electrophoresis.TALANTA,69(4),996-1000.
MLA Yang, BC,et al."An integrated light emitting diode-induced fluorescence detector for capillary electrophoresis".TALANTA 69.4(2006):996-1000.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Yang, BC]'s Articles
[Tian, HZ]'s Articles
[Xu, J]'s Articles
Baidu academic
Similar articles in Baidu academic
[Yang, BC]'s Articles
[Tian, HZ]'s Articles
[Xu, J]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Yang, BC]'s Articles
[Tian, HZ]'s Articles
[Xu, J]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.